Chicken Heat Shock Protein 70 (HSP-70) Elisa Kit Instructions

Chicken Heat Shock Protein 70 (HSP-70) Elisa Kit Instructions This kit is for research use only.
Detection range: 96T
10 ng / L -400 ng / L
purpose of usage:
This kit is used to determine the content of heat shock protein-70 (HSP-70) in chicken serum, plasma and related liquid samples.
Experimental Principle Chicken Heat Shock Protein 70 (HSP-70) Elisa Kit Instructions This kit uses the double antibody sandwich method to determine the level of chicken heat shock protein-70 (HSP-70) in the specimen. Microporous plates were coated with purified chicken heat shock protein-70 (HSP-70) antibody to make solid-phase antibodies. Heat shock protein-70 (HSP-70) was added to the microwells coated with monoclonal antibody in turn, followed by HRP-labeled heat shock protein-70 (HSP-70) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The shade of color and the heat shock protein-70 in the sample
(HSP-70) was positively correlated. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of chicken heat shock protein-70 (HSP-70) in the sample was calculated by a standard curve.
Kit composition
1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (800ng / L) 0.5ml × 1 bottle
3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B solution 6ml × 1 / bottle 12 sealed bag 1 specimen requirement
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.
400 ng / L No. 5 standard 150μl original standard added 150μl standard dilution
200 ng / L No. 4 standard 150μl No. 5 standard added 150μl standard dilution
100 ng / L No. 3 standard 150μl No. 4 standard added 150μl standard dilution
50 ng / L No. 2 standard 150 μl No. 3 standard added 150 μl standard dilution
25 ng / L No. 1 standard 150μl No. 2 standard added 150μl standard diluent
2. Add sample: set up blank wells separately (the blank control wells do not add samples and enzyme label reagents, the rest of the steps are the same), standard wells,
Sample hole to be tested. Add 50μl of the standard on the enzyme-coated plate accurately, and add 40μl of sample diluent to the sample well.
Then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds, then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark
15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Summary of operating procedures:
The calculation takes the concentration of the standard as the abscissa and the OD value as the ordinate, and draws a standard curve on the coordinate paper.
The corresponding concentration of OD value is found from the standard curve; then multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration With a dilution factor,
This is the actual concentration of the sample.
Precautions
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months Chicken Heat Shock Protein 70 (HSP-70) Elisa Kit Instructions

Fashion And Jewelry Display Rack

China Jewelry Display Rack manufacturer.

High-end jewelry display racks can enhance the image of the brand.

Jewelry display racks serve primarily as carriers for displaying jewelry.

Jewelry display stands can protect jewelry from external damage.

Maximize the beauty and value of jewelry.

Attract customers' attention.

Our jewelry display stands do unique design.

Can be very good for you to establish the brand image of your jewelry business.

Our designers will consider all the characteristics of jewelry in detail.

As well as display needs and brand image and other factors.

Then choose the material that can best highlight the value and beauty of jewelry.

Meet the display image of jewelry.

We can according to your store space and customer flow and other circumstances.

We can design the best jewelry display layout and size for you.

Allow customers to experience the unique charm and value of the brand completely.

Help your customers better appreciate your goods and boost sales.

If you need to buy jewellery display stands, please contact us.

Jewelry Display Rack,Buy Jewellery Display Stands,Jewelry Display Stands for sale,wholesale jewelry display racks

Dongguan Display Leader Co., Ltd , https://www.ddlretaildisplay.com