How to calibrate the on-line quotation electronic platform scale?

How to Correctly Correct the Alarm Electronic Scale The alarm electronic scale has the characteristics of convenient use and easy operation. When using it, you don't need to look at the display screen. You can directly look at the alarm light. Generally, it is used in the workshop to check whether the product is qualified. Although the use of the alarm electronic scale is very simple, the calibration method is still necessary and must be handled carefully.

How to calibrate the on-line quotation electronic platform scale?

1: Turn on the machine to zero, press the “Clear button” button to enter the setting state, and display “UER6.0”;

2: Enter the password "123456" to enter the setting of full weighing and sensitivity;

3: Press the “Accumulate Confirmation” button to select the “Return to Zero” and “Buckle” options.

4: Press the “return to zero” button and the “deduction” button to select the full weighing, and the “upper and lower limit” button to increase or decrease the number of zeros;

5: Press the “Accumulate Confirmation” button once, input the calibration weight value, put the weight, and wait for stability;

6: Press the “Accumulate Confirmation” button twice to linearly track to about 12000 (the internal code is about 200,000 or so the sensor is bad) and automatically enter the calibration;

7: Press the “Accumulate Confirmation” button twice, then press the “Single Reset Cancel” button once to display the corresponding value, ie OK.

8: Press the “Accumulate Confirmation” button once, to display PASS;

Function umbrella