A salt spray test chamber is a device that simulates a dispersion system composed of tiny salt-containing droplets in the atmosphere. It is used for the salt spray corrosion test of the plating, coating, etc. of products, parts, metal materials and products such as electronics, electricians, automobiles, motorcycles, hardware tools, etc.
Salt spray test box can not spray the cause of failure:
1. The air compressor is not running;
2. The main switch of the air compressor outlet is not turned on;
3. Solenoid valve failure;
4. The pressure gauge is faulty or the pressure is too low;
5. Electromagnetic contactor failure;
6. The nozzle is blocked;
Solution for salt spray test chamber:
1. Turn on the air compressor button;
2. Turn on the air compressor main switch;
3, 4, 5. Notify the maintenance company to come home for repair;
6. Remove and clean the nozzle (please disassemble carefully).
This article is an original article by Beijing Yashilin. Please be sure to indicate the source when reprinting: Beijing Yashilin Test Equipment Co., Ltd.